Mandatory Water Conservation
Must earn two points regardless of whether Performance or Prescriptive SmartRegs Pathway is chosen. Points earned in this category do not count towards Prescriptive 100 point requirement.
*Points awarded based on average of all fixtures in unit
**Points awarded if all faucets are equipped with self closing valves.
Please refer to the SmartRegs Guidebook for further clarification.| Water Conservation Measure | Points |
|---|
| Low flow showerhead* | 1 |
| Low flow lavatory faucets* | 1 |
| Self closing faucet valves** | 1 |
| High efficiency or dual flush toilet* | 2 |
| ENERGY STAR washing machine | 2 |
| ENERGY STAR dishwasher | 2 |
Floors / Foundations
Slab on Grade
| TYPE | 25% | 50% | 75% | 100% |
|---|
| Slab Edge: R-0 | 2 | 3 | 5 | 6 |
| Slab Edge: >R-5 | 2 | 4 | 5 | 7 |
| Slab Edge: >R-10 | 2 | 4 | 6 | 8 |
| Slab Edge: >R-10 AND Under Slab: >R-10 | 3 | 6 | 8 | 11 |
Below Grade (Basement Slab)
| Type | 25% | 50% | 75% | 100% |
|---|
| Basement Slab | 2 | 4 | 6 | 8 |
|---|
Foundation Walls (Crawlspace)
| Type | 25% | 50% | 75% | 100% |
|---|
| R-0 | 0 | 0 | 0 | 0 |
|---|
| R-2 | 2 | 3 | 5 | 6 |
|---|
| R-11 | 2 | 4 | 6 | 8 |
|---|
| >R-19 | 2 | 5 | 7 | 9 |
|---|
Framed Floors
(Only Available if No Ducts or HVAC Equipment are Located in Unconditioned Space Below Floor)
| Type | 25% | 50% | 75% | 100% |
|---|
| Framed Floor: R-0 | 0 | 0 | 0 | 0 |
|---|
| Framed Floor: R-13 | 3 | 5 | 8 | 11 |
|---|
| Framed Floor: R-25 | 3 | 6 | 9 | 12 |
|---|
| Framed Floor: >R-38 | 4 | 7 | 11 | 14 |
|---|
| Shared Floor | 4 | 8 | 11 | 15 |
|---|
Score
Distribution System
| LOCATION / INSULATION | 25% | 50% | 75% | 100% |
|---|
Uninsulated Pipes/Ducts (In Unconditioned Space) | 0 | 0 | 0 | 0 |
Pipes/Ducts Insulated (R 4) (In Unconditioned Space) | 1 | 3 | 4 | 6 |
| Pipes / Ducts Within Conditioned Space | 2 | 3 | 5 | 7 |
Score
Note
*Historically designated properties and properties older than 50 years with wooden window frames that rehabilitate and install storm panels will receive credit at the 0.35 U Value level.
Other
| Measure | POINTS |
|---|
| Heat Pump Desuperheater | 1 |
| Electronically Commutated Motor (“ECM”) | 3 |
| Passive Solar Design | Discretionary – approved by City of Boulder |
| Innovative Practice | Discretionary – approved by City of Boulder |
| Technically Impractical: Carbon Offsets | Must be Approved by City of Boulder (8 points per metric ton of CO2 offset) |
Score
Note
*Qualifying installations include power purchase agreements, solar leases, or verified subscription in Community Solar Garden.
**Units must earn 70 prescriptive pathway points in other categories to be eligible to earn PV points.